鍍(du)(du)鋅(xin)(xin)鋼管(guan)(guan)(guan)(guan)分為熱鍍(du)(du)鋅(xin)(xin)鋼管(guan)(guan)(guan)(guan)和冷(leng)鍍(du)(du)鋅(xin)(xin)鋼管(guan)(guan)(guan)(guan)兩種,熱鍍(du)(du)鋅(xin)(xin)鋼管(guan)(guan)(guan)(guan)鋅(xin)(xin)層厚,具有鍍(du)(du)層均勻、附著力強、使用(yong)(yong)(yong)壽(shou)命長(chang)等優點。冷(leng)鍍(du)(du)鋅(xin)(xin)(電鍍(du)(du))成(cheng)本低,其本身的耐蝕性比熱鍍(du)(du)鋅(xin)(xin)鋼管(guan)(guan)(guan)(guan)差很多。由于熱鍍(du)(du)鋅(xin)(xin)鋼管(guan)(guan)(guan)(guan)的耐蝕性比較強,因此,冷(leng)鍍(du)(du)鋅(xin)(xin)鋼管(guan)(guan)(guan)(guan)用(yong)(yong)(yong)量在逐漸減(jian)少(shao),熱鍍(du)(du)鋅(xin)(xin)鋼管(guan)(guan)(guan)(guan)的使用(yong)(yong)(yong)占主導地位。熱鍍(du)(du)鋅(xin)(xin)鋼管(guan)(guan)(guan)(guan)在國內可按GB/T 3091《低壓(ya)流體輸送用(yong)(yong)(yong)焊接鋼管(guan)(guan)(guan)(guan)》標準。


  鍍鋅管常用于工廠空氣、儀表空氣、煤氣、暖氣等,鍍鋅管作為水管,管內易產生銹垢,且夾雜著不光滑內壁滋生的細菌,銹蝕造成水中重金屬含量過高,近些年常用不銹(xiu)鋼管(guan)或塑料管(或內襯塑料管)替代。


    ①. 有的項目規定每段一定長度的管子加法(fa)蘭,法蘭與管子焊接后統一進行鍍鋅,再到施工現場用法蘭螺栓連接。


    ②. 有的項目消(xiao)防噴淋系統管道主要(yao)以螺紋和焊(han)(han)接法(fa)蘭連接為主。焊(han)(han)接法(fa)蘭接口(kou)破壞了接口(kou)附近的鍍(du)鋅層,需要(yao)二(er)次鍍(du)鋅處理,成本(ben)高(gao),工期長。


工程應用:鍍鋅管道配管連接的錯誤


  如圖2.110所示,筆(bi)者在某施(shi)工現場(chang)發現鍍(du)(du)鋅管(guan)子與(yu)彎(wan)頭的(de)(de)(de)連(lian)接(jie)采用了直接(jie)焊(han)(han)接(jie),鍍(du)(du)鋅管(guan)子與(yu)普(pu)通碳鋼(未鍍(du)(du)鋅)的(de)(de)(de)法蘭直接(jie)焊(han)(han)接(jie)連(lian)接(jie)。在施(shi)工過程中,連(lian)接(jie)的(de)(de)(de)位置就(jiu)已經開始(shi)腐(fu)蝕生銹(xiu),管(guan)內(nei)壁(bi)的(de)(de)(de)生銹(xiu)狀況可想而知。施(shi)工結束(shu)前只是在管(guan)子外壁(bi)補鍍(du)(du)鋅油漆(qi),而管(guan)子內(nei)壁(bi)焊(han)(han)縫無法補鍍(du)(du)鋅。這(zhe)種不好的(de)(de)(de)設(she)計,也會造成(cheng)鍍(du)(du)鋅管(guan)子內(nei)壁(bi)焊(han)(han)縫位置的(de)(de)(de)腐(fu)蝕,會影響(xiang)流體的(de)(de)(de)潔(jie)凈度,這(zhe)樣就(jiu)沒有必要用鍍(du)(du)鋅管(guan)了。


110.jpg


  鍍(du)鋅(xin)(xin)鋼管的(de)連接(jie)方式,通(tong)常為(wei)螺紋、溝槽卡箍、法(fa)蘭等,如果采用了焊(han)接(jie),需要進行補(bu)鍍(du)鋅(xin)(xin)和整體再鍍(du)鋅(xin)(xin)。


  例(li)如,GB50084 自(zi)動(dong)噴(pen)水滅火系統設計規范內(nei)明(ming)確(que)規定(ding):“配水管(guan)(guan)(guan)(guan)(guan)(guan)道(dao)(dao)應(ying)采用(yong)內(nei)外壁熱鍍鋅(xin)鋼(gang)管(guan)(guan)(guan)(guan)(guan)(guan)(或(huo)符合現行國(guo)家(jia)或(huo)行業標準(zhun)的銅管(guan)(guan)(guan)(guan)(guan)(guan)、不銹鋼(gang)管(guan)(guan)(guan)(guan)(guan)(guan)等(deng)管(guan)(guan)(guan)(guan)(guan)(guan)道(dao)(dao))。當報警閥(fa)入口前管(guan)(guan)(guan)(guan)(guan)(guan)道(dao)(dao)采用(yong)不防(fang)腐的鋼(gang)應(ying)在(zai)該(gai)段管(guan)(guan)(guan)(guan)(guan)(guan)道(dao)(dao)的末端(duan)設過濾器。鍍鋅(xin)鋼(gang)管(guan)(guan)(guan)(guan)(guan)(guan)應(ying)采用(yong)溝(gou)槽(cao)式連接(jie)件(卡箍(gu))、螺紋(wen)或(huo)法(fa)蘭連接(jie)口。報警閥(fa)前采用(yong)內(nei)壁不防(fang)腐鋼(gang)管(guan)(guan)(guan)(guan)(guan)(guan)時,可焊(han)接(jie)連接(jie)。系統中直徑(jing)等(deng)于或(huo)大(da)于100mm的管(guan)(guan)(guan)(guan)(guan)(guan)道(dao)(dao),應(ying)分段采用(yong)法(fa)蘭或(huo)溝(gou)槽(cao)式連接(jie)件(卡箍(gu))連接(jie)。水平管(guan)(guan)(guan)(guan)(guan)(guan)道(dao)(dao)上法(fa)蘭間的管(guan)(guan)(guan)(guan)(guan)(guan)道(dao)(dao)長度(du)不宜(yi)大(da)于20m;立管(guan)(guan)(guan)(guan)(guan)(guan)上法(fa)蘭間的距(ju)離,不應(ying)跨越3個及以(yi)上樓層(ceng)。”這個規范對鍍鋅(xin)鋼(gang)管(guan)(guan)(guan)(guan)(guan)(guan)的連接(jie)方式作出了強制規定(ding),如果使用(yong)了熱鍍鋅(xin)鋼(gang)管(guan)(guan)(guan)(guan)(guan)(guan),則需采用(yong)溝(gou)槽(cao)式管(guan)(guan)(guan)(guan)(guan)(guan)道(dao)(dao)連接(jie)件(卡箍(gu))、螺紋(wen)或(huo)法(fa)蘭連接(jie),不允(yun)許管(guan)(guan)(guan)(guan)(guan)(guan)段之(zhi)間焊(han)接(jie)。


工(gong)程應用(yong):鍍(du)鋅管(guan)道(dao)的(de)埋(mai)地設計


  筆者(zhe)在參加某裝置配(pei)管(guan)(guan)(guan)設(she)計(ji)審(shen)查時,發現裝置管(guan)(guan)(guan)廊上(shang)多出15根DN200的鍍(du)(du)鋅(xin)消(xiao)防(fang)用管(guan)(guan)(guan)道(dao),從(cong)配(pei)管(guan)(guan)(guan)設(she)計(ji)人那里了(le)解到,他們(men)認為(wei)鍍(du)(du)鋅(xin)鋼管(guan)(guan)(guan)不能埋地(di),所以(yi)他們(men)把所有的消(xiao)防(fang)水管(guan)(guan)(guan)道(dao)布置在了(le)管(guan)(guan)(guan)廊上(shang)。其實,鍍(du)(du)鋅(xin)鋼管(guan)(guan)(guan)可以(yi)埋地(di)設(she)計(ji),埋地(di)時做防(fang)腐蝕處理就可。消(xiao)防(fang)用水管(guan)(guan)(guan)道(dao)的埋地(di)設(she)計(ji)更加符合(he)安全設(she)計(ji)要求,對整個(ge)裝置更加經濟和美觀。