①. 熱水(shui)熱力網管(guan)(guan)(guan)道地(di)下(xia)敷(fu)(fu)(fu)(fu)設(she)時(shi),應優先采(cai)(cai)用(yong)(yong)(yong)直(zhi)埋敷(fu)(fu)(fu)(fu)設(she);熱水(shui)或蒸(zheng)汽管(guan)(guan)(guan)道采(cai)(cai)用(yong)(yong)(yong)管(guan)(guan)(guan)溝(gou)敷(fu)(fu)(fu)(fu)設(she)時(shi),應首選不通行管(guan)(guan)(guan)溝(gou)敷(fu)(fu)(fu)(fu)設(she);穿越不允許開挖檢修的地(di)段時(shi),應采(cai)(cai)用(yong)(yong)(yong)通行管(guan)(guan)(guan)溝(gou)敷(fu)(fu)(fu)(fu)設(she);當采(cai)(cai)用(yong)(yong)(yong)通行管(guan)(guan)(guan)溝(gou)困(kun)難時(shi),可采(cai)(cai)用(yong)(yong)(yong)半(ban)通行管(guan)(guan)(guan)溝(gou)敷(fu)(fu)(fu)(fu)設(she)。蒸(zheng)汽管(guan)(guan)(guan)道采(cai)(cai)用(yong)(yong)(yong)管(guan)(guan)(guan)溝(gou)敷(fu)(fu)(fu)(fu)設(she)困(kun)難時(shi),可采(cai)(cai)用(yong)(yong)(yong)保溫性能良好、防水(shui)性能可靠、保護(hu)管(guan)(guan)(guan)耐腐(fu)蝕的預(yu)制保溫管(guan)(guan)(guan)直(zhi)埋敷(fu)(fu)(fu)(fu)設(she),其設(she)計(ji)壽命應不低于25年(nian)。


 ②. 河(he)(he)(he)底敷(fu)(fu)設(she)(she)管(guan)(guan)道(dao)必須遠(yuan)離(li)淺灘、錨地,選擇在(zai)(zai)較深的穩定(ding)河(he)(he)(he)段(duan),埋(mai)設(she)(she)深度應(ying)(ying)按不(bu)妨礙河(he)(he)(he)道(dao)整治和保(bao)證管(guan)(guan)道(dao)安全(quan)的原則確定(ding)。對于一至五級航(hang)道(dao)河(he)(he)(he)流,管(guan)(guan)道(dao)(管(guan)(guan)溝(gou))應(ying)(ying)敷(fu)(fu)設(she)(she)在(zai)(zai)航(hang)道(dao)底設(she)(she)計標高2m以(yi)下(xia),對于其他河(he)(he)(he)流,管(guan)(guan)道(dao)(管(guan)(guan)溝(gou))應(ying)(ying)敷(fu)(fu)設(she)(she)在(zai)(zai)穩定(ding)河(he)(he)(he)底1m以(yi)下(xia)。對于灌溉渠道(dao),管(guan)(guan)道(dao)(管(guan)(guan)溝(gou))應(ying)(ying)敷(fu)(fu)設(she)(she)在(zai)(zai)渠底設(she)(she)計標高0.5m以(yi)下(xia)。管(guan)(guan)溝(gou)敷(fu)(fu)設(she)(she)或直(zhi)埋(mai)敷(fu)(fu)設(she)(she)管(guan)(guan)道(dao)河(he)(he)(he)底敷(fu)(fu)設(she)(she)時,應(ying)(ying)進行抗浮計算(suan)。


 ③. 熱力網管(guan)道同河流、鐵路(lu)、公路(lu)等交叉(cha)時應垂直相交。特殊情況下,管(guan)道與(yu)鐵路(lu)或(huo)地下鐵路(lu)交叉(cha)角(jiao)度不得(de)(de)小(xiao)于(yu)60°;管(guan)道與(yu)河流或(huo)公路(lu)交叉(cha)角(jiao)度不得(de)(de)小(xiao)于(yu)45°。


 ④. 地下敷設(she)管(guan)(guan)道(dao)與(yu)鐵(tie)路或(huo)不(bu)允許開挖(wa)的(de)公路交叉,交叉段的(de)一側(ce)留有足夠的(de)抽管(guan)(guan)檢修地段時,可采用(yong)(yong)套管(guan)(guan)敷設(she)。套管(guan)(guan)敷設(she)時,套管(guan)(guan)內不(bu)應(ying)(ying)采用(yong)(yong)填(tian)充式(shi)保溫,管(guan)(guan)道(dao)保溫層與(yu)套管(guan)(guan)間應(ying)(ying)留有不(bu)小于50mm的(de)空隙。套管(guan)(guan)內的(de)管(guan)(guan)道(dao)及其(qi)他鋼部件(jian)應(ying)(ying)采取(qu)加強防腐(fu)措施。采用(yong)(yong)鋼套管(guan)(guan)時,套管(guan)(guan)內、外表面均應(ying)(ying)進行防腐(fu)處理。


 ⑤. 地下敷設(she)熱力(li)網(wang)管(guan)道(dao)和管(guan)溝應(ying)設(she)坡(po)度,其坡(po)度不小于0.002。進入建筑物的管(guan)道(dao)應(ying)坡(po)向干管(guan)。地上敷設(she)的管(guan)道(dao)可不設(she)坡(po)度。


 ⑥. 地(di)下(xia)(xia)敷設熱力(li)網(wang)管道(dao)的覆土(tu)深度應符(fu)合下(xia)(xia)列規定。


   a. 管溝蓋(gai)(gai)板或檢查室蓋(gai)(gai)板覆土(tu)深度不應小于0.2m。


   b. 直埋敷設管(guan)道(dao)的最小覆土(tu)深(shen)度(du)應考慮土(tu)壤和地面活荷載(zai)對(dui)管(guan)道(dao)強度(du)的影響(xiang)并保證管(guan)道(dao)不發生縱向失穩。具體規定應按(an)CJJ/T 81《城(cheng)鎮直埋供熱管(guan)道(dao)工程技術規程》規定執行。


 ⑦. 燃氣管(guan)(guan)(guan)(guan)道不得進(jin)入(ru)熱(re)力(li)網管(guan)(guan)(guan)(guan)溝(gou)。當自來水(shui)管(guan)(guan)(guan)(guan)道、排(pai)水(shui)管(guan)(guan)(guan)(guan)道或(huo)(huo)電纜(lan)與熱(re)力(li)網管(guan)(guan)(guan)(guan)道交叉必(bi)須穿(chuan)入(ru)熱(re)力(li)網管(guan)(guan)(guan)(guan)溝(gou)時,應加套管(guan)(guan)(guan)(guan)或(huo)(huo)用厚度不小于100mm的(de)(de)混凝土防護(hu)層(ceng)與管(guan)(guan)(guan)(guan)溝(gou)隔(ge)開,同時不得妨礙熱(re)力(li)管(guan)(guan)(guan)(guan)道的(de)(de)檢修及地溝(gou)排(pai)水(shui)。套管(guan)(guan)(guan)(guan)應伸出(chu)管(guan)(guan)(guan)(guan)溝(gou)以外,每側不應小于1m。


 ⑧. 熱力(li)網管(guan)(guan)溝(gou)與燃(ran)氣(qi)管(guan)(guan)道(dao)交(jiao)叉當垂直凈距(ju)小于300mm時,燃(ran)氣(qi)管(guan)(guan)道(dao)應(ying)(ying)加套管(guan)(guan)。套管(guan)(guan)兩端應(ying)(ying)超出管(guan)(guan)溝(gou)1m以上。




聯系方式.jpg